Application

This product is fit for power transmission with rated voltage up to 35 kV.


Type and Designation

Basic type

Designation

Standard

Copper core

Al core

YJV

YJY

YJV22

YJV32

YJV42

YJV62

YJV72

YJLV

YJLY

YJLV22

YJLV32

YJLV42

YJLV62

YJLV72

XLPE insulated PVC sheathed power cable
XLPE insulated PE sheathed power cable
XLPE insulated steel tape armoured PVC sheathed power cable
XLPE insulated fin steel wire armoured PVC sheathed power cable
XLPE insulated fine steel wire armoured PVC sheathed power cable
XLPE insulated dual non-magnetic metal tape armoured PVC sheathed power cable
XLPE insulated non-magnetic metal tape armoured PVC sheathed power cable

IEC60502-2
GB/T12706.2~.3


Specification

Type

Number of core

Rated voltage Uo/U kV

3.6/6、6/6

6/10、8.7/10、8.7/15

12/20

18/30、21/35、26/35

Nominal cross-section mm2

YJV
YJY
YJV62
YJV72

YJLV
YJLY
YJLV62
YJLV72

1

25~630

25~630

35~630

50~630

YJV
YJY
YJV22
YJV32
YJV42
YJV62
YJV72

YJLV
YJLY
YJLV22
YJLV32
YJLV42
YJLV62
YJLV72

3

25~500

25~500

35~500

50~500


Structure Figure


Insulation thickness

Nominal cross-section
mm2

Nominal insulation thickness at rated voltage
mm

3.6/6(7.2)kV

6/6(7.2) kV
6/10(12) kV

8.7/10(12) kV
8.7/15(17.5) kV

12/20(24) kV

18/30(36) kV

21/35(40.5) kV

26/35(40.5) kV

25
35
50~185
240
300
400
500~1000

2.5
2.5
2.5
2.6
2.8
3.0
3.2

3.4
3.4
3.4
3.4
3.4
3.4
3.4

4.5
4.5
4.5
4.5
4.5
4.5
4.5


5.5
5.5
5.5
5.5
5.5
5.5



8.0
8.0
8.0
8.0
8.0



9.3
9.3
9.3
9.3
9.3



10.5
10.5
10.5
10.5
10.5


Technical parameter

●D.C resistance of the conductor can comply with regulation in IEC60228、GB/T3956.

●Inductance and earthing capacitance.


Inductance and capacitance of single cable

Nominal cross-section
mm2

Voltage rating kV

3.6/6

6/6、6/10

8.7/10、8.5/15

12/20

18/30

21/35

26/35

inductance

capacitance

inductance

capacitance

inductance

capacitance

inductance

capacitance

inductance

capacitance

inductance

capacitance

inductance

capacitance

25
35
50
70
95
120
150
185
240
300
400
500
630

0.240
0.408
0.385
0.366
0.344
0.331
0.315
0.308
0.301
0.296
0.295
0.288
0.281

0.24
0.26
0.30
0.34
0.38
0.42
0.46
0.50
0.54
0.56
0.61
0.68
0.76

0.433
0.411
0.398
0.379
0.354
0.344
0.334
0.322
0.313
0.302
0.299
0.291
0.283

0.19
0.21
0.24
0.27
0.30
0.32
0.35
0.38
0.42
0.47
0.55
0.63
0.71

0.449
0.427
0.414
0.392
0.369
0.360
0.350
0.341
0.325
0.314
0.309
0.298
0.289

0.15
0.18
0.19
0.22
0.24
0.26
0.28
0.30
0.34
0.37
0.41
0.45
0.51


0.459
0.436
0.414
0.392
0.379
0.366
0.350
0.341
0.328
0.318
0.307
0.298


0.16
0.17
0.19
0.21
0.23
0.25
0.27
0.29
0.32
0.36
0.41
0.45



0.448
0.432
0.413
0.394
0.398
0.375
0.361
0.341
0.332
0.328
0.312


0.13
0.15
0.16
0.17
0.19
0.20
0.22
0.24
0.26
0.32
0.34



0.467
0.455
0.436
0.417
0.404
0.392
0.376
0.360
0.347
0.355
0.339



0.12
0.14
0.15
0.16
0.17
0.18
0.20
0.22
0.23
0.25
0.30



0.513
0.487
0.465
0.446
0.430
0.417
0.394
0.373
0.361
0.354
0.342



0.11
0.12
0.13
0.14
0.15
0.16
0.18
0.19
0.21
0.23
0.26


Inductance and capacitance of 3-core cable

Nominal cross-section
mm2

Voltage rating kV

3.6/6

6/6、6/10

8.7/10、8.5/15

12/20

18/30

21/35

26/35

inductance

capacitance

inductance

capacitance

inductance

capacitance

inductance

capacitance

inductance

capacitance

inductance

capacitance

inductance

capacitance

25
35
50
70
95
120
150
185
240
300
400
500

0.363
0.351
0.331
0.314
0.301
0.289
0.280
0.273
0.266
0.263
0.259
0.254

0.70
0.78
0.90
1.02
1.14
1.26
1.38
1.50
1.62
1.68
1.83
1.91

0.395
0.376
0.357
0.336
0.322
0.309
0.299
0.291
0.281
0.273
0.265
0.260

0.51
0.63
0.72
0.81
0.90
0.96
1.05
1.14
1.26
1.41
1.65
1.82

0.424
0.401
0.379
0.360
0.341
0.325
0.316
0.305
0.296
0.286
0.277
0.270

0.45
0.54
0.57
0.66
0.72
0.78
0.84
0.90
1.02
1.11
1.41
1.68


0.424
0.398
0.379
0.363
0.344
0.334
0.322
0.301
0.300
0.290
0.283


0.48
0.51
0.57
0.63
0.69
0.75
0.81
0.87
0.96
1.08
1.21


0.413
0.397
0.382
0.367
0.353
0.346
0.331
0.325
0.317
0.308


0.47
0.54
0.60
0.65
0.71
0.75
0.81
0.92
1.01
1.12


0.486
0.450
0.417
0.402
0.382
0.367
0.352
0.337
0.326
0.317


0.41
0.48
0.52
0.58
0.63
0.69
0.76
0.85
0.97
1.05


0.528
0.503
0.427
0.412
0.398
0.382
0.366
0.352
0.339
0.326


0.38
0.42
0.48
0.52
0.57
0.62
0.70
0.79
0.92
0.97


Other electrical performance

Rated voltage U0/U

kV

3.6/6

6/6
6/10

8.7/10
8.7/15

12/20

18/30

21/35

26/35

Route test









Partial discharge

Voltage discharge≤

kV

PC

6.3

10

10.5

10

15.2

10

20.9

10

31.2

10

36.4

10

45.0

10

A.C voltage test 

Time

kV

min

12.5

5

21

5

30.5

5

42

5

63

5

73.5

5

91

5

Type test









Partial discharge 

Voltage discharge≤

kV

PC

6.3

5

10.5

5

15.2

5

20.9

5

31.2

5

36.4

5

45.0

5

Impact voltage test

kV

60

75

95

125

170

250

250

4 hours A.C voltage test

kV

14.4

24

34.8

48

72

84

104


Feature

●XLPE insulated cable has good electrical and heat resistant performance.

●Compared with oil filled cable, it has no risk of oil leakage, and cable laying will not effected by the fall.

●It can bear long-term operating network voltage, and various over voltage encountered in the normal operating, such as over voltage by operation, by the atmosphere, by the fault.

●It can transmit the power reliable.

●It has good mechanical strength, bending, and corrosion, destroy flame-retardant performance.

●It has no pollution, and has a long usage life.

Working condition

●Max.operating temperature of the conductor:90℃.

●In short circuit condition (Max.continual period shall not exceed 5 S ), Max. temperature of the conductor shall not exceed 250℃.

●laying surrounding temperature 0℃.

●Permitted bend radius of the cable: shall not less than 15 times of outer diameter of the cable for the single cable, and shall not less than 20 times of outer diameter of the cable for three core cable.

http://www.chinaxintongcable.com/

Inquiry